Hazardous area

Explosion-proof perimeter alarm

Detection and alarm inside the hazardous area, not at its edge.

Series / models
Ex d IIB T6 Gb / Ex ib IIC T6 detector family
Detection
Ex-rated IR, gas, smoke, heat, vibration
Typical range
IR 1–100 m; gas 5–20 m²; smoke 60–80 m²
Control
Relay / Ex-rated control outside the zone
Explosion-proof detectors installed on an industrial wall
Ex d IIB T6 Gb / Ex ib IIC T6 detector familySYSTEM VIEW
Explosion-proof infrared barrier pair
Explosion-proof detector enclosure with Ex marking
Overview

Explosion-proof perimeter alarm

Ex d IIB T6 GbIP65 / IP66304 stainless hardware
At a glance
Ex codeEx d IIB T6 Gb
IR range1–100 m
Gas alarm8% LEL
RatingIP65 / IP66
Capabilities that matter on site

Detection and alarm inside the hazardous area, not at its edge.

01

Ex-rated enclosures

Flameproof and intrinsically safe designs cover Ex d IIB T6 Gb, Ex d IIC T6 Gb and Ex ib IIC T6, for Zone 1 and Zone 2 gas environments.

02

Corrosion-resistant hardware

Fasteners are 304 stainless steel and the viewing windows use explosion-proof glass with high light transmission.

03

Barrier, curtain and detector

Two-, three- and four-beam barriers cover 1–100 m; four- to ten-beam curtains cover 1–80 m; microwave/PIR detectors cover 1–10 m at the door or wall.

04

Gas, smoke and heat

Combustible gas (8% LEL ±3%), smoke, temperature/humidity and vibration detectors share the same hazardous-area mounting logic.

05

Audible and visual alarm

The Ex alarm sounder delivers ≥90 dB with 150 flashes per minute and is rated Ex d IIC T6 / DIP A20.

How detection works

From principle to site

Values are typical manufacturer data. Site conditions, power supply and configuration can change the final specification.

Start from the zone classification

The detector you can use is decided by the area classification drawing, not by the product catalogue. Confirm whether the location is Zone 1 or Zone 2, which gas group (IIA, IIB or IIC) and which temperature class (T1–T6) applies. A detector rated Ex d IIB T6 is not interchangeable with an Ex ib IIC T6 device; they solve different problems and require different wiring.

Explosion-proof does not mean maintenance-free. Flameproof joints must not be painted, filed or opened in the hazardous area; intrinsic-safe circuits need their own isolators and cable parameters. Include the certification documents and the installation drawing in the handover pack.

Layered detection for tank farms and loading areas

Use explosion-proof infrared barriers or curtains along the perimeter wall, vibration detectors on the fence or tank shell, gas detectors at the pump and loading points, and an Ex sounder for local alarm. The control equipment sits outside the hazardous area, connected through suitable barriers or isolators.

Avoid placing the beam across a loading arm’s normal travel or a tank’s relief path. A detector that alarms during every transfer will be bypassed within a week. Mark the detection envelope on the site plan and review it with operations before installation.

Specifications

Technical specifications

Values are typical manufacturer data. Site conditions, power supply and configuration can change the final specification.

Technical specifications
Certification codesEx d IIB T6 Gb; Ex d IIC T6 Gb; Ex ib IIC T6; DIP A20 Ta, T6
IR barrier beams2 / 3 / 4 beams
IR barrier range1–100 m
IR curtain beams4 / 6 / 8 / 10 beams; 1–80 m
Microwave/PIR range1–10 m; 110° wide angle / 15° curtain
Gas detection8% LEL ±3%; 5–20 m²; DN15 / G1/2 thread
Smoke detection0.10–0.27 dB/m; 60–80 m² protection
Temperature/humidityRS485, MODBUS RTU; 10–20 m²
Vibration detectorDC8–18 V; 6-level sensitivity; NO/NC
Alarm sounder≥90 dB; 150 flashes/min; DC12 V; 5 W
IR barrier powerDC12–24 V; 2 W
Operating temperature−40 °C to +60 °C; RH < 95%
ProtectionIP65 / IP66
OutputDry NO/NC relay; 12 V siren where applicable
Frequently asked questions

Buyer questions

Which certificates should be supplied?

Ask for the explosion-proof certificate for each model, the marking plate photograph showing the Ex code, the installation and maintenance manual, and the certificate for any associated isolator or barrier. The certificate must match the area classification, gas group and temperature class.

Can standard CCTV cameras be used in the same area?

Only if the camera is in an appropriate explosion-proof housing and the cable entry is rated for the area. A standard camera in a weatherproof housing is not acceptable in a Zone 1 or Zone 2 location, even if it is mounted high up.

How is the gas detector calibrated?

Calibrate with the target gas or a certified surrogate at the specified flow rate, following the manufacturer’s interval. The published alarm point is 8% LEL ±3%; record the zero and span values and keep the calibration tag on the device.

What maintenance is allowed inside the hazardous area?

Visual inspection, cleaning of the window with a damp cloth and replacement of parts explicitly permitted by the manual. Opening a flameproof enclosure or disconnecting an intrinsic-safe circuit usually requires a gas-free permit and isolation; follow the site procedure.

Specify this system for your perimeter

Specify this system for your perimeter

Send the perimeter length, fence or wall type and the response requirement. We will return a zone plan and a configuration.