Glossary
Electric fence & perimeter terms
The vocabulary used in specifications, tender documents and installation drawings.
- Terms
- 24
Control & integration
- Alarm zone
- The smallest segment of perimeter that reports its own alarm. Zone size is set by the response plan: how far a guard can travel and still verify the event.
- Dry contact
- A relay output that provides a voltage-free open/closed signal. It is the most universal interface between a sensor and a third-party alarm panel or camera input.
- False alarm / nuisance alarm
- An alarm triggered by something other than the threat the system was designed to detect: wind, animals, vegetation, maintenance work or a failing component. The cause should be fixed, not only the sensitivity lowered.
- Fence host
- The energizer and controller for a pulse or tension fence. It generates the pulse or reads the tension module, reports alarms and provides relay or network outputs.
- NB-IoT
- Narrowband Internet of Things: a low-power cellular standard for small data messages. Used for remote perimeter barriers where no cable route exists.
- RS485
- A differential serial bus used for daisy-chained devices over twisted-pair cable. Common in perimeter hosts and control keyboards; it does not support star wiring.
- Zone map
- A site plan showing every zone boundary, name, device address, camera preset and response route. It is a controlled document, not a one-off drawing.
Detection
- Alloy wire
- The magnesium-aluminium wire strung between fence posts in a pulse fence. Typical specification is φ0.66 mm × 7 strands, chosen for oxidation resistance and low conductivity.
- Bi-polar pulse
- A pulse fence arrangement in which adjacent wires sit at different potentials. A jumper across two wires creates a short circuit instead of silently equalising the line.
- Buried leakage cable
- Two parallel cables buried a few centimetres below the surface that create an electromagnetic field. A person crossing the field disturbs it and triggers the detector.
- DTS (distributed temperature sensing)
- A fibre-optic technique that measures temperature continuously along a cable, used for cable trays, tunnels and conveyors. It measures heat, not motion.
- Fibre interferometer
- A sensing method that detects vibration by measuring changes in the interference pattern of light travelling through a fibre. Used in vibration and locating fibre systems.
- Laser barrier
- A transmitter and receiver pair using a narrow laser beam. A person interrupting the beam triggers an alarm. Range and beam count depend on the model.
- Leakage cable
- A coaxial cable designed to radiate a controlled electromagnetic field. Used in buried detection, where two cables form a sensing field above the ground.
- PIR (passive infrared)
- A detector that senses changes in infrared radiation caused by a moving body. Often combined with microwave in a dual-technology detector to reduce false alarms.
- Pulse duration
- The length of one high-voltage pulse, typically ≤0.1 s for an electronic fence. Short duration is a safety feature; it limits the energy delivered to a contact.
- Pulse energy
- The charge delivered in one pulse, often expressed in millicoulombs (mC). It is a better safety indicator than voltage alone; a fence catalog may list ≤2.5 mC.
- Tension fence
- A fence whose wires are held under tension and connected to a strain module. Climbing, lifting or cutting changes the tension and triggers an alarm. No voltage on the fence.
- Vibration fibre
- A fibre-optic sensing system that detects vibration along a cable bonded to a fence, wall or ground. It can report a zone, or a position with a locating processor.
Compliance
- Ex d
- Flameproof protection: the enclosure contains an internal explosion and prevents it from propagating to the surrounding atmosphere. Common marking for hazardous-area detectors.
- Ex ib
- Intrinsic safety with two independent faults considered. The circuit energy is limited so that it cannot ignite the surrounding atmosphere, even under fault conditions.
Installation
- IP rating
- Ingress protection: the first digit is dust, the second is water. IP65 is dust-tight and protected against water jets; IP66 adds protection against powerful jets.
- Sterile zone
- A clear strip between two perimeter layers where nothing is stored and vegetation is controlled. It gives the inner sensor a clean detection field and the guard a safe inspection area.
- Terminal post
- The post at the end of a fence zone or at a corner that takes the full wire tension. Terminal posts are usually no more than 100 m apart in a pulse fence.
From metres to energizer